It is a basic health and safety requirement to monitor bacteria levels in swimming pools and spas on a regular basis. Beacon Water Treatments Ltd can offer routine microbiological sampling in accordance with the current guidelines for sites throughout the United Kingdom. Our nominated independent laboratories are located throughout the UK, operate to identical high standards of quality control, and are accredited under the United Kingdom Accreditation Services (UKAS) for a wide range of determinands. Please refer to the Water Testing documents for some general information; these can be downloaded from the Data Sheets section above. Cooling Systems The revised ACoP requires service providers to ensure that measures put in place to control the risk of exposure to legionella are designed and carried out to be effective, safe and without risk to health when used. It is also stipulates that an on-going dialogue between the provider and the client’s responsible person is maintained. Beacon Water Treatments Ltd. is able to provide you with all necessary back-up to ensure that your system operates within the required parameters of compliance with current legislation and guidelines. Our expert team of experienced field staff are trained to provide or advise on: Monthly on-site service Legionella control programmes Cleaning and sterilisation Tank cleaning and refurbishment Installation of dosing and other control equipment Servicing of Pre-treatment plant The responsibilities placed upon operators of cooling systems under the Health & Safety at Work Act and the revised ACoP are such that the operator must take reasonable care to ensure that the service provider of his choosing is competent to carry out the requirements expected to advise and carry out work on his behalf. A Code of Conduct has been drawn up by the British Association for Chemical Specialities (BACS) and the Legionella Control Association (LCA) which sets out the 6 areas that should be addressed by the service provider. Beacon Water Treatments attempts to conduct all its activities within the requirements of the Code. Steam and LPHW Boiler Plant The use of chemical treatments for boiler plants to control scaling and corrosion potential is long established. It is however necessary to ensure that such treatment programmes are monitored on a regular basis to ensure economic control. Our fully trained field staff...
In circumstances where the Health & Safety at Work Act is applicable the HSE’s Approved Code of Practice (ACOP) L8 requires that a risk assessment be carried out to identify risks of legionella associated from water sources and work activities undertaken on the premises. Most undertakings with hot water facilities will require such an assessment and it is a legal requirement where wet cooling towers or evaporative condensers are utilised. To comply with their responsibilities under the Act, operators of cooling systems should: Identify and assess sources of risk Prepare a scheme for preventing or controlling such risk Keep records of the precautions Appoint a Responsible Person Beacon Water Treatments Limited can assist you to comply with these requirements by carrying out a full Legionella Risk Assessment on the water services installed at your premises. The assessment will include a full report on the condition of plant and systems, details of remedial works (if any) required to ensure compliance, schematics of the plant and systems concerned, and a Written Scheme for the control of the risk. For further details and an indication of costs involved please contact...
Products
Since 1982 Beacon have been blending chemical additives for use in heat exchange processes. Cooling Towers, Evaporative Condensers, Steam Boilers and Hot Water Boilers all pose problems of one sort or another in regard to their efficiency, maintenance, cleanliness and safety. Beacon’s range of 80 water treatment chemical products provides you with the opportunity to ensure that your systems are maintained within, and comply with, current legislative and guidance parameters. Our cooling and boiler water inhibitors and biocides have been developed and formulated over many years and are regularly reviewed within our ISO 9001 quality control system to take account of advances within the industry. Cooling systems suffer from scale and corrosion problems Cooling systems suffer from bacterial fouling problems Steam Boilers suffer from scale and corrosion problems Closed system LPHW systems suffer from sludge build up! Potable systems suffer from corrosion and red water! To overcome these problems and obtain details of our product range, contact us today. Dosing & Control Equipment The best treatments in the world will be of little benefit if they remain in the drum in which they were delivered. The ACOP recommends that treatments for cooling systems be added automatically. We supply a full range of Dosing Equipment including: Chemical dosing pumps and Controllers Dosing/ bleed Controllers Brominators Redox Control Systems pH monitoring Pre-Treatment Equipment For the purposes of process water comes in two varieties, hard and soft. There are also many sources of water and these may be contaminated with iron, nitrates or other contaminants or they may be cloudy. There are circumstances where hard water may be a benefit but on the whole soft water is preferable for cooling and steam raising requirements, and water should preferably be clean and clear. Beacon provides a full range of pre-treatment plant for such applications: Base Exchange Water Softeners (Simplex or Duplex) Demineralisation Plants Nitrate Removal Plants Iron Removal Filters Activated Carbon Filters pH Correction Filters To discover how we may be of assistance to you for your present or future requirements contact our quotation...
Beacon Water Treatments Ltd can offer routine microbiological sampling in accordance with the current guidelines for sites throughout the United Kingdom.